Publication detail
Aberration correction for low voltage optimized transmission electron microscopy
BAČOVSKÝ, J.
English title
Aberration correction for low voltage optimized transmission electron microscopy
Type
journal article in Web of Science
Language
en
Original abstract
Further development of low voltage electron microscopy leads to an aberration correction of the device in order to improve its spatial resolution. The integration of a corrector to a desktop transmission electron microscope with exclusively low-voltage design seems to be a challenging task. The benefits and potential of the Rose hexapole corrector implemented to such a system are critically considered in this paper. The feasibility of miniaturized corrector suitable for desktop LVEM is especially discussed, including the aspect of corrector contribution to chromatic aberration that appears to be crucial. Optimal corrector parameters and resolution limits of such a system are proposed. Improved spatial resolution Spherical aberration correction Permanent magnet transfer lenses (C) 2018 DELONG INSTRUMENTS a.s. Published by Elsevier B.V.
English abstract
Further development of low voltage electron microscopy leads to an aberration correction of the device in order to improve its spatial resolution. The integration of a corrector to a desktop transmission electron microscope with exclusively low-voltage design seems to be a challenging task. The benefits and potential of the Rose hexapole corrector implemented to such a system are critically considered in this paper. The feasibility of miniaturized corrector suitable for desktop LVEM is especially discussed, including the aspect of corrector contribution to chromatic aberration that appears to be crucial. Optimal corrector parameters and resolution limits of such a system are proposed. Improved spatial resolution Spherical aberration correction Permanent magnet transfer lenses (C) 2018 DELONG INSTRUMENTS a.s. Published by Elsevier B.V.
Keywords in English
Low voltage transmission electron microscopy; Aberration correction; Hexapole corrector
Released
25.08.2018
Publisher
Elsevier
Location
AMSTERDAM
ISSN
2215-0161
Volume
5
Number
1
Pages from–to
1033–1047
Pages count
15
BIBTEX
@article{BUT169885,
author="Jaromír {Bačovský},
title="Aberration correction for low voltage optimized transmission electron microscopy",
year="2018",
volume="5",
number="1",
month="August",
pages="1033--1047",
publisher="Elsevier",
address="AMSTERDAM",
issn="2215-0161"
}